Liberty Center One
Liberty Center One is an operational data center operated by Liberty Center One in Royal Oak, United States. Our footprint estimate of its power is about 2.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Liberty Center One |
| Facility power | 2.4 MW (range 1.2 MW to 3.8 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,991 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 5 networks PeeringDB. |
| Address | 4815 Delemere Ave |
| Coordinates | 42.53351, -83.17739 |
| Website | libertycenterone.com |
Power and grid
| Nearest high-voltage substation | Formtech Substation, 120 kV, 500 m away (DTE Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Red Run Substation, 230 kV, 11.6 km away |
| HV substations within 10 km | 12 |
| Utility | Dte Electric Company (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | MISO |
| Nearest gas pipeline | Panhandle Eastern PL Co, interstate pipeline, 1.9 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.9 GW in 23 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 455 g CO₂ per kWh (Michigan, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 42%, coal 23.2%, nuclear 21.7%, wind 8%, solar 2.6%. Clean power: 34.5% |
| Industrial power price | USD 0.090 per kWh (Michigan, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 36.7 °C (2001 to 2025) |
| Cooling degree days | 351 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.78 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Low - Medium (10-20%) (Michigan) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Liberty Center One use?
We estimate the facility power at about 2.4 MW. Estimate from building footprint, low confidence.
How close is Liberty Center One to the power grid?
The nearest high-voltage substation in OpenStreetMap is Formtech Substation (120 kV), about 500 m away. The local utility is Dte Electric Company, in the MISO balancing area.
How clean is the power for Liberty Center One?
The grid in Michigan emits about 455 g CO₂ per kWh (2025). Largest sources: gas 42%, coal 23.2%, nuclear 21.7%.
Who operates Liberty Center One?
Liberty Center One.
Data centers near Royal Oak
- ManagedWay TYM1 6.4 km
- ManagedWay TYM2 6.5 km
- 123.NET - DC1 - 24700 Northwestern Hwy. 8.5 km
- ManagedWay SFJ2 8.8 km
- 365 Data Centers Detroit (DT1) 9.8 km
- EdgeConneX Detroit (EDCDET01) 11.7 km · 6.5 MW
- Chick-fil-A Hiring Center 18.7 km
- Tesla 10k H100 Cluster 21.1 km · 15 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.