EdgeConneX Detroit (EDCDET01)
EdgeConneX Detroit (EDCDET01) is an operational data center operated by EdgeConneX in Southfield, United States. Our footprint estimate of its power is about 6.5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | EdgeConneX |
| Facility power | 6.5 MW (range 3.3 MW to 10 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,419 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 15 networks, 1 internet exchanges PeeringDB. |
| Also known as | EDCDET01 · EdgeConneX Detroit DET01 |
| Address | 21005 Lahser Rd, Bldg 4 |
| Coordinates | 42.44854, -83.26123 |
| Website | edgeconnex.com |
Power and grid
| Nearest high-voltage substation | Northwest Substation, 120 kV, 2.6 km away (Detroit Edision) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Warren Substation, 230 kV, 13.6 km away |
| HV substations within 10 km | 11 |
| Utility | Dte Electric Company (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | MISO |
| Nearest gas pipeline | Michcon Gas Co, intrastate pipeline, 4.6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.3 GW in 25 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 455 g CO₂ per kWh (Michigan, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 42%, coal 23.2%, nuclear 21.7%, wind 8%, solar 2.6%. Clean power: 34.5% |
| Industrial power price | USD 0.090 per kWh (Michigan, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 8.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.3 °C (2001 to 2025) |
| Cooling degree days | 358 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.79 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Low - Medium (10-20%) (Michigan) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does EdgeConneX Detroit (EDCDET01) use?
We estimate the facility power at about 6.5 MW. Estimate from building footprint, low confidence.
How close is EdgeConneX Detroit (EDCDET01) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Northwest Substation (120 kV), about 2.6 km away. The local utility is Dte Electric Company, in the MISO balancing area.
How clean is the power for EdgeConneX Detroit (EDCDET01)?
The grid in Michigan emits about 455 g CO₂ per kWh (2025). Largest sources: gas 42%, coal 23.2%, nuclear 21.7%.
Who operates EdgeConneX Detroit (EDCDET01)?
EdgeConneX.
Data centers near Southfield
- 365 Data Centers Detroit (DT1) 2.4 km
- ManagedWay SFJ2 3.0 km
- 123.NET - DC1 - 24700 Northwestern Hwy. 3.2 km
- Liberty Center One 11.7 km · 2.4 MW
- ManagedWay TYM1 16.5 km
- ManagedWay TYM2 16.8 km
- Otava Metro Detroit 18.4 km
- Verizon Wireless data center in Detroit 20.3 km · 4.6 MW
More EdgeConneX data centers
- EdgeConneX PHX02 Data Center United States
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConnex DUB04 Ireland
- EdgeConneX Germany
- EdgeConneX Chicago (EDCCHI02) United States
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConnex - DEN02 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.