Meta Sarpy Data center
Meta Sarpy Data center is an operational data center operated by Meta in Chalco, United States. Our footprint estimate of its power is about 79 MW. Likely chips: NVIDIA GPUs (some Meta MTIA) (guess).
Key facts
| Status | Operational |
|---|---|
| Operator | Meta |
| Facility power | 79 MW (range 40 MW to 127 MW) Estimate from building footprint, low confidence. Footprint estimate: about 66,240 m² building outline x 1 floor(s) x 1.2 kW/m². |
| AI chips | NVIDIA GPUs (some Meta MTIA) Guess from the operator, not confirmed. Meta trains on NVIDIA GPUs and adds in-house MTIA chips for inference. |
| GPU capacity if all AI | about 34,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 41.11225, -96.14162 |
Power and grid
| Nearest high-voltage substation | 150th St & Capehart Rd Substation, 161 kV, 700 m away (Omaha Public Power District) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 345 kV, 2.6 km away |
| HV substations within 10 km | 17 |
| Utility | Omaha Public Power District (political subdivision) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SWPP |
| Nearest gas pipeline | Northern Natural Gas Co, interstate pipeline, 900 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.2 GW in 11 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 460 g CO₂ per kWh (Nebraska, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 46%, wind 29.4%, nuclear 17.4%, gas 3.2%, hydro 2.9%. Clean power: 50.7% |
| Industrial power price | USD 0.084 per kWh (Nebraska, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 43.1 °C (2001 to 2025) |
| Cooling degree days | 707 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.16 kWh per m² per day |
| Wind at 50 m | 7.1 m/s average |
| Water stress today | Extremely High (>80%) (Nebraska) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Meta Sarpy Data center use?
We estimate the facility power at about 79 MW. Estimate from building footprint, low confidence.
What chips does Meta Sarpy Data center use?
No chips are reported. Based on the operator, the likely chips are NVIDIA GPUs (some Meta MTIA).
How close is Meta Sarpy Data center to the power grid?
The nearest high-voltage substation in OpenStreetMap is 150th St & Capehart Rd Substation (161 kV), about 700 m away. The local utility is Omaha Public Power District, in the SWPP balancing area.
How clean is the power for Meta Sarpy Data center?
The grid in Nebraska emits about 460 g CO₂ per kWh (2025). Largest sources: coal 46%, wind 29.4%, nuclear 17.4%.
Who operates Meta Sarpy Data center?
Meta.
Data centers near Chalco
- Meta Sarpy Data center 254 m · 151 MW
- Sarpy Meta Data Center 345 m · 128 MW
- Sarpy Meta Data Center 1.1 km · 52 MW
- Sarpy Meta Data Center 1.3 km · 56 MW
- Travelers Insurance 1.8 km · 17 MW
- Google 2.5 km · 25 MW
- Google Papillion Data Center 2.7 km · 113 MW
- Google 2.7 km · 25 MW
More Meta data centers
- Meta Hyperion United States
- QTS Cedar Rapids United States
- Meta Prometheus United States
- Meta Bowling Green United States
- Meta Montgomery United States
- QTS Eagle Mountain United States
- Meta Huntsville Data Center United States
- Altoona Meta Data Center United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.