Pewaukee Data Center
Pewaukee Data Center is an operational data center operated by WE Energies in Waukesha, United States. Our footprint estimate of its power is about 10 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | WE Energies |
| Facility power | 10 MW (range 5.2 MW to 17 MW) Estimate from building footprint, low confidence. Footprint estimate: about 8,608 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Busse Road W237N1500, 53188, Waukesha |
| Coordinates | 43.05137, -88.21670 |
Power and grid
| Nearest high-voltage substation | Waukesha Substation, 138 kV, 2.7 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Arcadian Substation, 345 kV, 5.9 km away |
| HV substations within 10 km | 5 |
| Utility | Wisconsin Electric Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | MISO |
| Nearest gas pipeline | ANR Pipeline Co, interstate pipeline, 6.6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.9 GW in 18 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 530 g CO₂ per kWh (Wisconsin, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 35.3%, coal 34.8%, nuclear 15.2%, solar 6.6%, hydro 3.3%. Clean power: 29.8% |
| Industrial power price | USD 0.109 per kWh (Wisconsin, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 8.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40 °C (2001 to 2025) |
| Cooling degree days | 352 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.67 kWh per m² per day |
| Wind at 50 m | 7 m/s average |
| Water stress today | Medium - High (20-40%) (Wisconsin) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Pewaukee Data Center use?
We estimate the facility power at about 10 MW. Estimate from building footprint, low confidence.
How close is Pewaukee Data Center to the power grid?
The nearest high-voltage substation in OpenStreetMap is Waukesha Substation (138 kV), about 2.7 km away. The local utility is Wisconsin Electric Power Co, in the MISO balancing area.
How clean is the power for Pewaukee Data Center?
The grid in Wisconsin emits about 530 g CO₂ per kWh (2025). Largest sources: gas 35.3%, coal 34.8%, nuclear 15.2%.
Who operates Pewaukee Data Center?
WE Energies.
Data centers near Waukesha
- Ethoplex Data Center 20.4 km
- TierPoint Milwaukee 21.3 km
- Data Holdings Milwaukee 21.4 km
- Vaultas 24.9 km
- 324 E Wisconsin 25.2 km
- CyberLynk MKE1 28.4 km
- Expedient Milwaukee 28.6 km · 2.7 MW
- Microsoft Fairwater Phase 2 46.2 km · 316 MW