QTS Data Center
QTS Data Center is an operational data center operated by Quality Technology Services in Roanoke, United States. Our footprint estimate of its power is about 37 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Quality Technology Services |
| Facility power | 37 MW (range 18 MW to 58 MW) Estimate from building footprint, low confidence. Footprint estimate: about 30,429 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 16,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 32.98891, -97.25927 |
Power and grid
| Utility | Denton County Elec Coop, INC (cooperative) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | ERCO |
| Nearest gas pipeline | Energy Transfer, intrastate pipeline, 8.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.7 °C (2001 to 2025) |
| Cooling degree days | 1,585 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.81 kWh per m² per day |
| Wind at 50 m | 6.6 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does QTS Data Center use?
We estimate the facility power at about 37 MW. Estimate from building footprint, low confidence.
How clean is the power for QTS Data Center?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates QTS Data Center?
Quality Technology Services.
Data centers near Roanoke
- QTS Fort Worth (FTW1) 79 m
- Facebook Fort Worth Datacenter 394 m · 153 MW
- Facebook Fort Worth Datacenter 570 m · 163 MW
- Facebook Fort Worth Datacenter 594 m · 88 MW
- TierPoint Dallas Forth Worth 1.2 km
- Charles Schwab Data Center 2.1 km · 7 MW
- CITIGROUP TECHNOLOGY INC 2.3 km · 21 MW
- Verizon Wireless Mew Building 9.7 km · 38 MW
More Quality Technology Services data centers
- QTS Richmond 1 United States
- QTS Piscataway Data Center United States
- QTS Richmond 2 Data Center United States
- QTS Richmond 3 Data Center United States
- QTS Ashburn 1 DC1 United States
- DC5 United States
- QTS United States
- QTS Ashburn-Shellhorn United States