SD / Comsat Southbury Ground Station
SD / Comsat Southbury Ground Station is an operational data center operated by SD Data Center in Southbury, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | SD Data Center |
| Networks | 1 networks PeeringDB. |
| Address | 2120 River Rd |
| Coordinates | 41.45160, -73.28939 |
| Website | satcomdirect.com/infrastructure-services/satellite-ground-stations |
Power and grid
| Nearest high-voltage substation | Shepaug Substation, 115 kV, 500 m away (Eversource) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Plumtree Substation, 345 kV, 11.5 km away |
| HV substations within 10 km | 5 |
| Utility | United Illuminating Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ISNE |
| Nearest gas pipeline | Algonquin Gas Trans Co, interstate pipeline, 1.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.8 GW in 38 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 308 g CO₂ per kWh (Connecticut, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 54.1%, nuclear 36.9%, solar 5.5%, oil and other fossil 1.4%, bioenergy 1.3%. Clean power: 44.6% |
| Industrial power price | USD 0.162 per kWh (Connecticut, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.1 °C (2001 to 2025) |
| Cooling degree days | 424 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.87 kWh per m² per day |
| Wind at 50 m | 4.3 m/s average |
| Water stress today | Low (<10%) (Connecticut) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is SD / Comsat Southbury Ground Station to the power grid?
The nearest high-voltage substation in OpenStreetMap is Shepaug Substation (115 kV), about 500 m away. The local utility is United Illuminating Co, in the ISNE balancing area.
How clean is the power for SD / Comsat Southbury Ground Station?
The grid in Connecticut emits about 308 g CO₂ per kWh (2025). Largest sources: gas 54.1%, nuclear 36.9%, solar 5.5%.
Who operates SD / Comsat Southbury Ground Station?
SD Data Center.
Data centers near Southbury
- HDC1 - 108 Bank St 23.6 km
- Aphorio Carter Trumbull Data Center 26.3 km · 32 MW
- Lumen West Haven 32.1 km
- Lumen New Haven 34.7 km
- CyrusOne data center in Norwalk 38.5 km · 13 MW
- CyrusOne Norwalk 39.0 km
- Data center in Wallingford 40.8 km · 4.9 MW
- Cloudpath CT1 (26 Fahey St) 44.3 km · 1.7 MW