Telehouse - Paris 3 (Magny)
Telehouse - Paris 3 (Magny) is an operational data center operated by Telehouse - Global Data Centers in Magny-les-Hameaux, France. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Telehouse - Global Data Centers |
| Networks | 51 networks, 4 internet exchanges PeeringDB. |
| Address | 1 Rue Pablo Picasso |
| Coordinates | 48.72693, 2.08147 |
| Website | telehouse.fr |
Power and grid
| Nearest high-voltage substation | Poste électrique de Saint-Aubin, 225 kV, 4.5 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 6 |
| Power plants within 50 km | 1.8 GW in 45 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.7 °C (2001 to 2025) |
| Cooling degree days | 130 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.31 kWh per m² per day |
| Wind at 50 m | 6.4 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Telehouse - Paris 3 (Magny) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique de Saint-Aubin (225 kV), about 4.5 km away.
How clean is the power for Telehouse - Paris 3 (Magny)?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Telehouse - Paris 3 (Magny)?
Telehouse - Global Data Centers.
Data centers near Magny-les-Hameaux
- Telehouse 3 299 m · 5.4 MW
- Datacenter 4.6 km · 5.5 MW
- Groupe Cyllene - DC - Montigny les Bretonneux 7.0 km
- Jean Zay Supercomputer 7.3 km · 2.4 MW
- Site technique SFR 7.3 km · 3.7 MW
- Site technique SFR 7.4 km · 2.9 MW
- Datacenter RTE 7.6 km
- Datacenter Bouygues Télécom 8.2 km · 9.8 MW
More Telehouse - Global Data Centers data centers
- Telehouse - London (Docklands South) United Kingdom
- Telehouse - Frankfurt Germany
- Telehouse - Hong Kong CCC (HKCOLO TKO) Hong Kong SAR China
- Telehouse – Bangkok Thailand
- Telehouse - Beijing BDA China
- Telehouse - Beijing BEZ China
- Telehouse - Hanoi Vietnam
- Telehouse - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.