Vantage Data Centers AZ2 Campus
Vantage Data Centers AZ2 Campus is a data center under construction in Goodyear, United States. Our footprint estimate of its power is about 14 MW.
Key facts
| Status | Under construction |
|---|---|
| Facility power | 14 MW (range 5.5 MW to 34 MW) Estimate from building footprint, low confidence. Footprint estimate: about 114,302 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 6,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | West Broadway Road 14575, 85338, Goodyear |
| Coordinates | 33.40462, -112.37282 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 230 kV, 700 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 4 |
| Utility | Salt River Project (political subdivision) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SRP |
| Nearest gas pipeline | El Paso Natural Gas Co, interstate pipeline, 1.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 14 GW in 41 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 311 g CO₂ per kWh (Arizona, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 43%, nuclear 25.6%, solar 17.5%, coal 7.5%, hydro 4.1%. Clean power: 49.8% |
| Industrial power price | USD 0.097 per kWh (Arizona, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 22.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 49.4 °C (2001 to 2025) |
| Cooling degree days | 2,422 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.85 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Extremely High (>80%) (Arizona) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Vantage Data Centers AZ2 Campus use?
We estimate the facility power at about 14 MW. Estimate from building footprint, low confidence.
How close is Vantage Data Centers AZ2 Campus to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (230 kV), about 700 m away. The local utility is Salt River Project, in the SRP balancing area.
How clean is the power for Vantage Data Centers AZ2 Campus?
The grid in Arizona emits about 311 g CO₂ per kWh (2025). Largest sources: gas 43%, nuclear 25.6%, solar 17.5%.
Data centers near Goodyear
- Microsoft Goodyear 889 m · 263 MW
- PHX-13 1.1 km · 21 MW
- Microsoft Goodyear Airpark Campus 1.2 km · 111 MW
- Stream Data Centers PHXA Campus 1.7 km · 47 MW
- Stream Phoenix 2.0 km · 77 MW
- Stack Infrastructure PHX01 Campus 2.1 km · 26 MW
- Data center in Goodyear 3.9 km · 35 MW
- Compass Datacenters Goodyear Campus 4.2 km · 84 MW