11:11 Systems
11:11 Systems is an operational data center in Mississauga, Canada. Our footprint estimate of its power is about 9.1 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 9.1 MW (range 4.6 MW to 15 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,598 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Argentia Road 1800, Mississauga |
| Coordinates | 43.60332, -79.73538 |
Power and grid
| Nearest high-voltage substation | Meadowvale TS, 230 kV, 4.9 km away (Hydro One) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 6 |
| Power plants within 50 km | 2.6 GW in 6 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 192 g CO₂ per kWh (Canada, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.8%, gas 19.7%, nuclear 12.8%, wind 8%, coal 2.7%. Clean power: 76.5% |
Climate and water
| Average temperature | 9.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 32.2 °C (2001 to 2025) |
| Cooling degree days | 288 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.65 kWh per m² per day |
| Wind at 50 m | 7 m/s average |
| Water stress today | Low - Medium (10-20%) (Ontario) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does 11:11 Systems use?
We estimate the facility power at about 9.1 MW. Estimate from building footprint, low confidence.
How close is 11:11 Systems to the power grid?
The nearest high-voltage substation in OpenStreetMap is Meadowvale TS (230 kV), about 4.9 km away.
How clean is the power for 11:11 Systems?
The grid in Canada emits about 192 g CO₂ per kWh (2025). Largest sources: hydro 52.8%, gas 19.7%, nuclear 12.8%.
Data centers near Mississauga
- Maxxam Analytics International Inc. 538 m · 19 MW
- CGI 906 m · 3.5 MW
- 11:11 Systems 1.3 km · 6.7 MW
- Cyxtera Toronto YYZ1 1.7 km · 12 MW
- Centersquare Toronto (YYZ1) 1.8 km
- CentriLogic Traders (TRA) 6.0 km
- Cogent Mississauga 2 7.9 km
- CentriLogic Mississauga (MIS) 8.0 km