Campus Santiago Ascenty Data Center

Campus Santiago Ascenty Data Center is an operational data center in Quilicura, Chile. Our footprint estimate of its power is about 11 MW.

Key facts

StatusOperational
Facility power11 MW (range 4.5 MW to 28 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 93,493 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 4,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asSCL03 · SCL02 · SCL01
AddressGuacolda 2100, Quilicura
Coordinates-33.33590, -70.70635
Websiteascenty.com/es/data-centers-es/ubicacion/chile

Power and grid

Nearest high-voltage substationSubestación Quilicura, 110 kV, 4 km away (Enel Distribución Chile)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationSubestación El Salto, 220 kV, 7.7 km away
HV substations within 10 km9
Power plants within 50 km1.0 GW in 83 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity291 g CO₂ per kWh (Chile, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 25.1%, hydro 22.2%, coal 17.8%, gas 15.3%, wind 13.1%. Clean power: 66.4%

Climate and water

Average temperature15.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.9 °C (2001 to 2025)
Cooling degree days445 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.42 kWh per m² per day
Wind at 50 m3.2 m/s average
Water stress todayExtremely High (>80%) (Chile)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Campus Santiago Ascenty Data Center use?

We estimate the facility power at about 11 MW. Estimate from building footprint, low confidence.

How close is Campus Santiago Ascenty Data Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is Subestación Quilicura (110 kV), about 4 km away.

How clean is the power for Campus Santiago Ascenty Data Center?

The grid in Chile emits about 291 g CO₂ per kWh (2025). Largest sources: solar 25.1%, hydro 22.2%, coal 17.8%.