Data Center Directory

CoreSite - Atlanta (AT2)

CoreSite - Atlanta (AT2) is an operational data center operated by CoreSite in Marietta, United States. Our footprint estimate of its power is about 7.2 MW.

Key facts

StatusOperational
OperatorCoreSite
Facility power7.2 MW (range 3.6 MW to 12 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 6,020 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,100 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks10 networks, 2 internet exchanges
PeeringDB.
Also known asCoreSite AT2 - Marietta Data Center
Address1130 Powers Ferry Pl
Coordinates33.92555, -84.48165
Websitecoresite.com

Power and grid

Nearest high-voltage substationUnnamed substation, 115 kV, 200 m away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationUnnamed substation, 230 kV, 2.9 km away
HV substations within 10 km36
UtilityCity Of Marietta (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authoritySOCO
Nearest gas pipelineSouthern Natural Gas Co, interstate pipeline, 20 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km6.3 GW in 13 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity352 g CO₂ per kWh (Georgia, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 38.7%, nuclear 34.8%, coal 13.6%, solar 8.1%, bioenergy 3.2%. Clean power: 47.6%
Industrial power priceUSD 0.131 per kWh (Georgia, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature16.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature42.1 °C (2001 to 2025)
Cooling degree days1,020 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.43 kWh per m² per day
Wind at 50 m4.5 m/s average
Water stress todayMedium - High (20-40%) (Georgia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does CoreSite - Atlanta (AT2) use?

We estimate the facility power at about 7.2 MW. Estimate from building footprint, low confidence.

How close is CoreSite - Atlanta (AT2) to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 200 m away. The local utility is City Of Marietta, in the SOCO balancing area.

How clean is the power for CoreSite - Atlanta (AT2)?

The grid in Georgia emits about 352 g CO₂ per kWh (2025). Largest sources: gas 38.7%, nuclear 34.8%, coal 13.6%.

Who operates CoreSite - Atlanta (AT2)?

CoreSite.

Data centers near Marietta

More CoreSite data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.