Data center in Asbury Park

Data center in Asbury Park is an operational data center in Asbury Park, United States. Our footprint estimate of its power is about 10 MW.

Key facts

StatusOperational
Facility power10 MW (range 5.2 MW to 17 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 8,601 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 4,300 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates40.20846, -74.11924

Power and grid

Nearest high-voltage substationAtlantic Substation, 230 kV, 5.1 km away (Jersey Central Power and Light)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km2
UtilityJersey Central Power & Lt Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineTranscontinental Gas PL, interstate pipeline, 29.5 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km8.7 GW in 114 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity536 g CO₂ per kWh (Ohio, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 54.9%, coal 24.4%, nuclear 11.7%, solar 5.8%, wind 2%. Clean power: 20%
Industrial power priceUSD 0.098 per kWh (Ohio, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.9 °C
NASA POWER, average of 2001 to 2025.
Highest temperature31.7 °C (2001 to 2025)
Cooling degree days472 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.01 kWh per m² per day
Wind at 50 m7.5 m/s average
Water stress todayLow - Medium (10-20%) (Ohio)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Data center in Asbury Park use?

We estimate the facility power at about 10 MW. Estimate from building footprint, low confidence.

How close is Data center in Asbury Park to the power grid?

The nearest high-voltage substation in OpenStreetMap is Atlantic Substation (230 kV), about 5.1 km away. The local utility is Jersey Central Power & Lt Co, in the PJM balancing area.

How clean is the power for Data center in Asbury Park?

The grid in Ohio emits about 536 g CO₂ per kWh (2025). Largest sources: gas 54.9%, coal 24.4%, nuclear 11.7%.