DataCenter.BZ - Worthington-Columbus
DataCenter.BZ - Worthington-Columbus is an operational data center operated by DataCenter.BZ in Worthington, United States. Our footprint estimate of its power is about 9.9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DataCenter.BZ |
| Facility power | 9.9 MW (range 4.9 MW to 16 MW) Estimate from building footprint, low confidence. Footprint estimate: about 8,237 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 5 networks PeeringDB. |
| Also known as | Datacenter.BZ · Cologix COL2 |
| Address | 535-575 Scherers Ct. |
| Coordinates | 40.11584, -83.00176 |
| Website | datacenter.bz |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 300 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Maliszewski Substation, 765 kV, 7.4 km away |
| HV substations within 10 km | 14 |
| Utility | City Of Columbus (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Columbia Gas Trans Co, interstate pipeline, 9.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 1.5 GW in 7 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 536 g CO₂ per kWh (Ohio, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 54.9%, coal 24.4%, nuclear 11.7%, solar 5.8%, wind 2%. Clean power: 20% |
| Industrial power price | USD 0.098 per kWh (Ohio, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38 °C (2001 to 2025) |
| Cooling degree days | 504 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.86 kWh per m² per day |
| Wind at 50 m | 6.3 m/s average |
| Water stress today | Low - Medium (10-20%) (Ohio) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DataCenter.BZ - Worthington-Columbus use?
We estimate the facility power at about 9.9 MW. Estimate from building footprint, low confidence.
How close is DataCenter.BZ - Worthington-Columbus to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 300 m away. The local utility is City Of Columbus, in the PJM balancing area.
How clean is the power for DataCenter.BZ - Worthington-Columbus?
The grid in Ohio emits about 536 g CO₂ per kWh (2025). Largest sources: gas 54.9%, coal 24.4%, nuclear 11.7%.
Who operates DataCenter.BZ - Worthington-Columbus?
DataCenter.BZ.
Data centers near Worthington
- Cologix COL1 75 m · 5.3 MW
- Cologix COL4 326 m · 9.1 MW
- WēConnect Westerville 5.0 km
- Centersquare Columbus (CMH1) 5.9 km
- Expedient Columbus - Upper Arlington 9.2 km
- DartPoints Dublin, OH - CMH1 11.5 km
- Expedient Columbus - Dublin 12.4 km
- Data center in Delaware 12.7 km · 32 MW