Digital Realty Atlanta ATL11

Digital Realty Atlanta ATL11 is an operational data center operated by Digital Realty in Austell, United States. Our footprint estimate of its power is about 30 MW.

Key facts

StatusOperational
OperatorDigital Realty
Facility power30 MW (range 15 MW to 49 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 25,298 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 13,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressAquila Way 101, 30122, Austell
Coordinates33.74656, -84.57974
Websitedigitalrealty.com/data-centers/atlanta/101-aquila-way-austell-ga

Power and grid

Nearest high-voltage substationGoogle Substation, 230 kV, 600 m away (Georgia Power)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km26
UtilityGreystone Power Corporation (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authoritySOCO
Nearest gas pipelineSouthern Natural Gas Co, interstate pipeline, 9.1 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.8 GW in 11 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity352 g CO₂ per kWh (Georgia, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 38.7%, nuclear 34.8%, coal 13.6%, solar 8.1%, bioenergy 3.2%. Clean power: 47.6%
Industrial power priceUSD 0.131 per kWh (Georgia, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature16.7 °C
NASA POWER, average of 2001 to 2025.
Highest temperature42.4 °C (2001 to 2025)
Cooling degree days1,093 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.51 kWh per m² per day
Wind at 50 m4.6 m/s average
Water stress todayMedium - High (20-40%) (Georgia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Digital Realty Atlanta ATL11 use?

We estimate the facility power at about 30 MW. Estimate from building footprint, low confidence.

How close is Digital Realty Atlanta ATL11 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Google Substation (230 kV), about 600 m away. The local utility is Greystone Power Corporation, in the SOCO balancing area.

How clean is the power for Digital Realty Atlanta ATL11?

The grid in Georgia emits about 352 g CO₂ per kWh (2025). Largest sources: gas 38.7%, nuclear 34.8%, coal 13.6%.

Who operates Digital Realty Atlanta ATL11?

Digital Realty.