Digital Realty CH2 - Chicago

Digital Realty CH2 - Chicago is an operational data center operated by Digital Realty in Elk Grove, United States. Our footprint estimate of its power is about 30 MW.

Key facts

StatusOperational
OperatorDigital Realty
Facility power30 MW (range 15 MW to 47 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 24,670 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 13,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asDigital Realty CH2
Address2299 Busse Road
Coordinates41.99418, -87.95768
Websitedigitalrealty.com

Power and grid

Nearest high-voltage substationTonne 138kV Substation, 138 kV, 1.7 km away (Commonwealth Edison)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationComEd Itasca 138kV-345kV Substation, 345 kV, 3.5 km away
HV substations within 10 km19
UtilityCommonwealth Edison Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineNorthern Illinois Gas Co, intrastate pipeline, 1.7 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.0 GW in 29 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.5 °C (2001 to 2025)
Cooling degree days465 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Digital Realty CH2 - Chicago use?

We estimate the facility power at about 30 MW. Estimate from building footprint, low confidence.

How close is Digital Realty CH2 - Chicago to the power grid?

The nearest high-voltage substation in OpenStreetMap is Tonne 138kV Substation (138 kV), about 1.7 km away. The local utility is Commonwealth Edison Co, in the PJM balancing area.

How clean is the power for Digital Realty CH2 - Chicago?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates Digital Realty CH2 - Chicago?

Digital Realty.

Data centers near Elk Grove

More Digital Realty data centers

Sources