Digital Realty EWR (100 Delawanna)
Digital Realty EWR (100 Delawanna) is an operational data center operated by Digital Realty in Clifton, United States. Our footprint estimate of its power is about 5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 5 MW (range 2.5 MW to 8 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,168 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 19 networks, 2 internet exchanges PeeringDB. |
| Also known as | NJDC1 - 100 Delawanna ave · Digital Realty New Jersey EWR20 |
| Address | 100 Delawanna Avenue, Building 1 |
| Coordinates | 40.82993, -74.12675 |
| Website | digitalrealty.com |
Power and grid
| Nearest high-voltage substation | East Rutherford Substation, 138 kV, 2.1 km away (Public Service Enterprise Group) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Belleville Substation, 230 kV, 3.3 km away |
| HV substations within 10 km | 26 |
| Utility | Public Service Elec & Gas Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 2.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 20 GW in 143 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 265 g CO₂ per kWh (New Jersey, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.8%, nuclear 43.2%, solar 9%, oil and other fossil 1.5%, bioenergy 0.9%. Clean power: 52.8% |
| Industrial power price | USD 0.162 per kWh (New Jersey, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.7 °C (2001 to 2025) |
| Cooling degree days | 504 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.87 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (New Jersey) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty EWR (100 Delawanna) use?
We estimate the facility power at about 5 MW. Estimate from building footprint, low confidence.
How close is Digital Realty EWR (100 Delawanna) to the power grid?
The nearest high-voltage substation in OpenStreetMap is East Rutherford Substation (138 kV), about 2.1 km away. The local utility is Public Service Elec & Gas Co, in the PJM balancing area.
How clean is the power for Digital Realty EWR (100 Delawanna)?
The grid in New Jersey emits about 265 g CO₂ per kWh (2025). Largest sources: gas 45.8%, nuclear 43.2%, solar 9%.
Who operates Digital Realty EWR (100 Delawanna)?
Digital Realty.
Data centers near Clifton
- Digital Realty EWR (2 Peekay) 169 m · 14 MW
- BT Radianz: 492 River Road 1.1 km · 17 MW
- Credit Suisse: Clifton Data Center 1.2 km · 27 MW
- 365 Data Centers Carlstadt (NJ3) 6.5 km
- H5 Data Centers Secaucus (NJ01) 6.6 km
- H5 Secaucus 6.6 km
- InterServer Teb2 6.6 km
- Evocative EWR1 6.8 km · 17 MW
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources