Digital Realty Madrid MAD4
Digital Realty Madrid MAD4 is an operational data center operated by Digital Realty in Madrid, Spain. Our footprint estimate of its power is about 9.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 9.7 MW (range 4.9 MW to 16 MW) Estimate from building footprint, low confidence. Footprint estimate: about 8,089 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 25 networks PeeringDB. |
| Also known as | MAD4 |
| Address | Calle de Alfonso Gómez 4 |
| Coordinates | 40.43893, -3.62945 |
| Website | digitalrealty.com/data-centers/emea/madrid/mad4 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 220 kV, 1.4 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 23 |
| Power plants within 50 km | 99 MW in 2 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 154 g CO₂ per kWh (Spain, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 21.9%, gas 21.5%, wind 20.4%, nuclear 18.8%, hydro 11.4%. Clean power: 74.6% |
| Industrial power price | EUR 0.105 per kWh (Spain, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 13.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.9 °C (2001 to 2025) |
| Cooling degree days | 623 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.7 kWh per m² per day |
| Wind at 50 m | 5.1 m/s average |
| Water stress today | High (40-80%) (Spain) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty Madrid MAD4 use?
We estimate the facility power at about 9.7 MW. Estimate from building footprint, low confidence.
How close is Digital Realty Madrid MAD4 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (220 kV), about 1.4 km away.
How clean is the power for Digital Realty Madrid MAD4?
The grid in Spain emits about 154 g CO₂ per kWh (2025). Largest sources: solar 21.9%, gas 21.5%, wind 20.4%.
Who operates Digital Realty Madrid MAD4?
Digital Realty.
Data centers near Madrid
- IaaS Datacenter Madrid 452 m
- Templus DC Madrid MAD03 542 m
- iaas data center in San Blas-Canillejas 542 m · 1.2 MW
- N1 636 m · 5.8 MW
- Digital Realty Madrid MAD1-2 699 m · 4.3 MW
- Digital Realty Madrid MAD3 721 m · 4 MW
- Cantabria Datacenter 3.8 km
- Espanix Datacenter 4.0 km
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.