Element Critical Chicago CH1
Element Critical Chicago CH1 is an operational data center operated by Element Critical in Wood Dale, United States. Our footprint estimate of its power is about 17 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Element Critical |
| Facility power | 17 MW (range 8.5 MW to 27 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,115 m² building outline x 2 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 7,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 2 networks PeeringDB. |
| Also known as | Element Critical CH1 |
| Address | 711 North Edgewood Ave |
| Coordinates | 41.97588, -87.96457 |
| Website | elementcritical.com |
Power and grid
| Nearest high-voltage substation | Tonne 138kV Substation, 138 kV, 2.5 km away (Commonwealth Edison) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | ComEd Itasca 138kV-345kV Substation, 345 kV, 2.6 km away |
| HV substations within 10 km | 19 |
| Utility | Commonwealth Edison Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Northern Illinois Gas Co, intrastate pipeline, 2.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.0 GW in 28 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 247 g CO₂ per kWh (Illinois, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3% |
| Industrial power price | USD 0.113 per kWh (Illinois, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.5 °C (2001 to 2025) |
| Cooling degree days | 465 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.67 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Medium - High (20-40%) (Illinois) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Element Critical Chicago CH1 use?
We estimate the facility power at about 17 MW. Estimate from building footprint, low confidence.
How close is Element Critical Chicago CH1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Tonne 138kV Substation (138 kV), about 2.5 km away. The local utility is Commonwealth Edison Co, in the PJM balancing area.
How clean is the power for Element Critical Chicago CH1?
The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.
Who operates Element Critical Chicago CH1?
Element Critical.
Data centers near Wood Dale
- CyrusOne CHI6 196 m · 4.8 MW
- Element Critical Chicago CH2 284 m · 7.8 MW
- Centersquare Chicago (ORD2) 1.9 km · 43 MW
- Digital Realty CH3 - Chicago 1.9 km · 35 MW
- Digital Realty CH1 - Chicago 2.1 km · 149 MW
- Skybox Chicago I 2.1 km · 50 MW
- Digital Realty CH2 - Chicago 2.1 km · 30 MW
- Stream Data Centers - Chicago II 2.6 km · 19 MW
More Element Critical data centers
- Element Critical Austin AUS1 United States
- Element Critical Northern Virginia VA1 United States
- Element Critical Chicago CH2 United States
- Element Critical Houston HOU1 United States