Element Critical Chicago CH1

Element Critical Chicago CH1 is an operational data center operated by Element Critical in Wood Dale, United States. Our footprint estimate of its power is about 17 MW.

Key facts

StatusOperational
OperatorElement Critical
Facility power17 MW (range 8.5 MW to 27 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 7,115 m² building outline x 2 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 7,300 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks
PeeringDB.
Also known asElement Critical CH1
Address711 North Edgewood Ave
Coordinates41.97588, -87.96457
Websiteelementcritical.com

Power and grid

Nearest high-voltage substationTonne 138kV Substation, 138 kV, 2.5 km away (Commonwealth Edison)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationComEd Itasca 138kV-345kV Substation, 345 kV, 2.6 km away
HV substations within 10 km19
UtilityCommonwealth Edison Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineNorthern Illinois Gas Co, intrastate pipeline, 2.2 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.0 GW in 28 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.5 °C (2001 to 2025)
Cooling degree days465 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Element Critical Chicago CH1 use?

We estimate the facility power at about 17 MW. Estimate from building footprint, low confidence.

How close is Element Critical Chicago CH1 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Tonne 138kV Substation (138 kV), about 2.5 km away. The local utility is Commonwealth Edison Co, in the PJM balancing area.

How clean is the power for Element Critical Chicago CH1?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates Element Critical Chicago CH1?

Element Critical.