Element Critical Northern Virginia VA1
Element Critical Northern Virginia VA1 is an operational data center operated by Element Critical in Vienna, United States. Our footprint estimate of its power is about 9.5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Element Critical |
| Facility power | 9.5 MW (range 4.7 MW to 15 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,882 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | Equinix DC7 |
| Address | 7990 Quantum Drive |
| Coordinates | 38.90861, -77.22047 |
| Website | elementcritical.com |
Power and grid
| Nearest high-voltage substation | Idylwood Substation, 230 kV, 2.7 km away (Dominion Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 11 |
| Utility | Virginia Electric & Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 11.6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.2 GW in 62 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 13.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.2 °C (2001 to 2025) |
| Cooling degree days | 748 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.04 kWh per m² per day |
| Wind at 50 m | 5.9 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Element Critical Northern Virginia VA1 use?
We estimate the facility power at about 9.5 MW. Estimate from building footprint, low confidence.
How close is Element Critical Northern Virginia VA1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Idylwood Substation (230 kV), about 2.7 km away. The local utility is Virginia Electric & Power Co, in the PJM balancing area.
How clean is the power for Element Critical Northern Virginia VA1?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Who operates Element Critical Northern Virginia VA1?
Element Critical.
Data centers near Vienna
- Equinix DC7 - Ashburn, Vienna 71 m
- Gosnell - International Gateway 1 (8100 Boone) 733 m · 13 MW
- DataBank McLean (IAD2) 1.3 km · 5.5 MW
- Level(3) McLean 1.5 km · 9.7 MW
- Equinix DC8 - Ashburn, Vienna 3.0 km
- Digital Realty IAD (1780 Business Center) 10.2 km · 17 MW
- Evocative Virginia (VA1) 10.4 km · 3.3 MW
- Flex Data Center 11.9 km
More Element Critical data centers
- Element Critical Chicago CH1 United States
- Element Critical Austin AUS1 United States
- Element Critical Chicago CH2 United States
- Element Critical Houston HOU1 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.