Element Critical Houston HOU1

Element Critical Houston HOU1 is an operational data center operated by Element Critical in Katy, United States. Our footprint estimate of its power is about 3.3 MW.

Key facts

StatusOperational
OperatorElement Critical
Facility power3.3 MW (range 1.3 MW to 8.2 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 27,219 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 1,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks, 1 internet exchanges
PeeringDB.
Also known asSkybox Houston One
Address22000 Franz rd
Coordinates29.80292, -95.75582
Websiteelementcritical.com

Power and grid

Nearest high-voltage substationFranz Substation, 138 kV, 200 m away (CenterPoint Energy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationZenith Substation, 345 kV, 12.1 km away
HV substations within 10 km4
UtilitySan Bernard Electric Coop, INC (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authorityERCO
Nearest gas pipelineGulf Connector Expansion Project, interstate pipeline, 300 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km9.3 GW in 27 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity379 g CO₂ per kWh (Texas, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8%
Industrial power priceUSD 0.072 per kWh (Texas, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature20.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature43.2 °C (2001 to 2025)
Cooling degree days1,787 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.65 kWh per m² per day
Wind at 50 m5.8 m/s average
Water stress todayHigh (40-80%) (Texas)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Element Critical Houston HOU1 use?

We estimate the facility power at about 3.3 MW. Estimate from building footprint, low confidence.

How close is Element Critical Houston HOU1 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Franz Substation (138 kV), about 200 m away. The local utility is San Bernard Electric Coop, INC, in the ERCO balancing area.

How clean is the power for Element Critical Houston HOU1?

The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.

Who operates Element Critical Houston HOU1?

Element Critical.

Data centers near Katy

More Element Critical data centers