Equinix AT1 - Atlanta
Equinix AT1 - Atlanta is an operational data center operated by Equinix in Atlanta, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Networks | 60 networks, 3 internet exchanges PeeringDB. |
| Also known as | Level(3) Atlanta (Peachtree) |
| Address | 180 Peachtree, 2nd and 6th Floors |
| Coordinates | 33.75857, -84.38787 |
| Website | equinix.com |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 115 kV, 800 m away (Georgia Power) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 230 kV, 1.6 km away |
| HV substations within 10 km | 43 |
| Utility | Georgia Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SOCO |
| Nearest gas pipeline | Southern Natural Gas Co, interstate pipeline, 6.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.9 GW in 8 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 352 g CO₂ per kWh (Georgia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 38.7%, nuclear 34.8%, coal 13.6%, solar 8.1%, bioenergy 3.2%. Clean power: 47.6% |
| Industrial power price | USD 0.131 per kWh (Georgia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 16.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.1 °C (2001 to 2025) |
| Cooling degree days | 1,020 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.43 kWh per m² per day |
| Wind at 50 m | 4.5 m/s average |
| Water stress today | Medium - High (20-40%) (Georgia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Equinix AT1 - Atlanta to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 800 m away. The local utility is Georgia Power Co, in the SOCO balancing area.
How clean is the power for Equinix AT1 - Atlanta?
The grid in Georgia emits about 352 g CO₂ per kWh (2025). Largest sources: gas 38.7%, nuclear 34.8%, coal 13.6%.
Who operates Equinix AT1 - Atlanta?
Equinix.
Data centers near Atlanta
- Southern Telecom 387 m
- Colo at 55, LLC 426 m
- Colo@34 (Downtown) 431 m
- Digital Realty ATL14 - Atlanta 464 m
- Equinix AT2/AT3 - Atlanta 484 m
- Level(3) Atlanta (Courtland) 825 m · 2 MW
- Databank Atlanta (ATL1) 1.9 km
- Google Fiber 2.4 km
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.