Equinix CU1/CU2/CU3/CU4 - Culpeper

Equinix CU1/CU2/CU3/CU4 - Culpeper is an operational data center operated by Equinix in Culpeper, United States. Our footprint estimate of its power is about 25 MW.

Key facts

StatusOperational
OperatorEquinix
Facility power25 MW (range 9.8 MW to 62 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 205,100 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 11,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks10 networks, 1 internet exchanges
PeeringDB.
Also known asEquinix CU2
Address18155 Technology Dr.
Coordinates38.45488, -77.97832
Websiteequinix.com

Power and grid

Nearest high-voltage substationMountain Run Substation, 115 kV, 1 km away (Virginia Electric and Power Company)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationRemington Substation, 230 kV, 19.9 km away
HV substations within 10 km4
UtilityRappahannock Electric Coop (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineTranscontinental Gas PL, interstate pipeline, 10.5 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.4 GW in 10 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity357 g CO₂ per kWh (Virginia, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39%
Industrial power priceUSD 0.100 per kWh (Virginia, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature41.1 °C (2001 to 2025)
Cooling degree days742 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.12 kWh per m² per day
Wind at 50 m4.2 m/s average
Water stress todayMedium - High (20-40%) (Virginia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Equinix CU1/CU2/CU3/CU4 - Culpeper use?

We estimate the facility power at about 25 MW. Estimate from building footprint, low confidence.

How close is Equinix CU1/CU2/CU3/CU4 - Culpeper to the power grid?

The nearest high-voltage substation in OpenStreetMap is Mountain Run Substation (115 kV), about 1 km away. The local utility is Rappahannock Electric Coop, in the PJM balancing area.

How clean is the power for Equinix CU1/CU2/CU3/CU4 - Culpeper?

The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.

Who operates Equinix CU1/CU2/CU3/CU4 - Culpeper?

Equinix.

Data centers near Culpeper

More Equinix data centers

Sources