Equinix HH1 - Hamburg
Equinix HH1 - Hamburg is an operational data center operated by Equinix in Hamburg, Germany. Our footprint estimate of its power is about 11 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 11 MW (range 5.6 MW to 18 MW) Estimate from building footprint, low confidence. Footprint estimate: about 9,251 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,700 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 5 networks, 1 internet exchanges PeeringDB. |
| Also known as | Equinix |
| Address | Vierenkamp 1 |
| Coordinates | 53.64479, 9.97477 |
| Website | equinix.de/locations/europe-colocation/germany-colocation/hamburg-data-centers/hh1 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 2.9 km away (Stromnetz Hamburg GmbH) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Hamburg Nord, 380 kV, 10.8 km away |
| HV substations within 10 km | 22 |
| Power plants within 50 km | 1.1 GW in 14 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 70 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.88 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Low (<10%) (Hamburg) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix HH1 - Hamburg use?
We estimate the facility power at about 11 MW. Estimate from building footprint, low confidence.
How close is Equinix HH1 - Hamburg to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 2.9 km away.
How clean is the power for Equinix HH1 - Hamburg?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Equinix HH1 - Hamburg?
Equinix.
Data centers near Hamburg
- GlobalConnect Hamburg (HAM1) 2.8 km
- NTT Hamburg 1 Data Center (HAM1) 2.8 km
- AtlasEdge DC Hamburg HAM001 3.3 km
- Penta Infra Hamburg HAM01 3.4 km
- Akquinet HAM02 4.9 km
- Akquinet HAM01 5.0 km
- Akquinet NOR01 6.3 km
- Stadtwerke Norderstedt RZ1 6.9 km
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.