Equinix PA10 - Paris, Saint-Denis
Equinix PA10 - Paris, Saint-Denis is an operational data center operated by Equinix in Paris, France. Our footprint estimate of its power is about 27 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 27 MW (range 14 MW to 44 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,701 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 12,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 18 networks, 3 internet exchanges PeeringDB. |
| Also known as | Equinix PA2 |
| Address | 114 Rue Ambroise Croizat, Saint Denis |
| Coordinates | 48.92817, 2.35208 |
| Website | equinix.com/data-centers/europe-colocation/france-colocation/paris-data-centers/pa10 |
Power and grid
| Nearest high-voltage substation | Poste électrique Seine, 225 kV, 1 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 58 |
| Power plants within 50 km | 2.2 GW in 53 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.6 °C (2001 to 2025) |
| Cooling degree days | 130 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.19 kWh per m² per day |
| Wind at 50 m | 6.3 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix PA10 - Paris, Saint-Denis use?
We estimate the facility power at about 27 MW. Estimate from building footprint, low confidence.
How close is Equinix PA10 - Paris, Saint-Denis to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique Seine (225 kV), about 1 km away.
How clean is the power for Equinix PA10 - Paris, Saint-Denis?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Equinix PA10 - Paris, Saint-Denis?
Equinix.
Data centers near Paris
- Equinix PA2 - Paris, Saint-Denis 152 m · 69 MW
- Ad Valem Technologies - France (Saint-Denis) 794 m
- Datacenter EDF 1.2 km
- Datacenter RTE 1.3 km
- Digital Realty Paris PAR3 1.7 km · 4 MW
- MCI/Verizon Paris St Denis 2.1 km
- Equinix PA6 - Paris, Condorcet 2.3 km · 9.2 MW
- nLighten Paris PAR2 2.6 km · 2.4 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.