Data Center Directory

Equinix SV17 - Silicon Valley, Santa Clara

Equinix SV17 - Silicon Valley, Santa Clara is an operational data center operated by Equinix in Santa Clara, United States. Our footprint estimate of its power is about 3.9 MW.

Key facts

StatusOperational
OperatorEquinix
Facility power3.9 MW (range 1.9 MW to 6.2 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 3,218 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks6 networks, 1 internet exchanges
PeeringDB.
Also known asEquinix SV17 · Equinix SV15 · Equinix SV16 · Equinix SV14
Address3030 Corvin Dr
Coordinates37.37635, -121.98859
Websiteequinix.com/locations/americas-colocation/united-states-colocation/silicon-valley-data-centers/sv17

Power and grid

Nearest high-voltage substationApplied Materials Substation, 115 kV, 1.6 km away (Pacific Gas and Electric Company)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationNorthern Receiving Station, 230 kV, 3.5 km away
HV substations within 10 km30
UtilityCity Of Santa Clara (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityCISO
Nearest gas pipelineCalifornia Gas Transmission Co, intrastate pipeline, 900 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km2.1 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity189 g CO₂ per kWh (California, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7%
Industrial power priceUSD 0.241 per kWh (California, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature14 °C
NASA POWER, average of 2001 to 2025.
Highest temperature45.3 °C (2001 to 2025)
Cooling degree days370 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.32 kWh per m² per day
Wind at 50 m4.6 m/s average
Water stress todayExtremely High (>80%) (California)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Equinix SV17 - Silicon Valley, Santa Clara use?

We estimate the facility power at about 3.9 MW. Estimate from building footprint, low confidence.

How close is Equinix SV17 - Silicon Valley, Santa Clara to the power grid?

The nearest high-voltage substation in OpenStreetMap is Applied Materials Substation (115 kV), about 1.6 km away. The local utility is City Of Santa Clara, in the CISO balancing area.

How clean is the power for Equinix SV17 - Silicon Valley, Santa Clara?

The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.

Who operates Equinix SV17 - Silicon Valley, Santa Clara?

Equinix.

Data centers near Santa Clara

More Equinix data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.