eStruxture TOR-5
eStruxture TOR-5 is an operational data center operated by eStruxture Data Centers in Barrie, Canada. Our footprint estimate of its power is about 8.2 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | eStruxture Data Centers |
| Facility power | 8.2 MW (range 4.1 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,847 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 5 networks, 1 internet exchanges PeeringDB. |
| Address | 612 Welham Rd, Barrie ON L4N 8Z8 |
| Coordinates | 44.33761, -79.67016 |
| Website | estruxture.com |
Power and grid
| Nearest high-voltage substation | Barrie TS, 230 kV, 4.9 km away (Hydro One) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 1 |
| Power plants within 50 km | 612 MW in 20 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 192 g CO₂ per kWh (Canada, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.8%, gas 19.7%, nuclear 12.8%, wind 8%, coal 2.7%. Clean power: 76.5% |
Climate and water
| Average temperature | 7.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34 °C (2001 to 2025) |
| Cooling degree days | 254 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.62 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
| Water stress today | Low - Medium (10-20%) (Ontario) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does eStruxture TOR-5 use?
We estimate the facility power at about 8.2 MW. Estimate from building footprint, low confidence.
How close is eStruxture TOR-5 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Barrie TS (230 kV), about 4.9 km away.
How clean is the power for eStruxture TOR-5?
The grid in Canada emits about 192 g CO₂ per kWh (2025). Largest sources: hydro 52.8%, gas 19.7%, nuclear 12.8%.
Who operates eStruxture TOR-5?
eStruxture Data Centers.
Data centers near Barrie
- Pathway Communications 59.0 km
- Rogers Data Center 60.0 km · 7.9 MW
- Cologix TOR4 60.1 km · 26 MW
- Equinix TR5 - Toronto 60.8 km · 12 MW
- Hut 8 GTA2 61.0 km
- Digital Realty YYZ10 Toronto (371 Gough) 62.0 km · 14 MW
- Centersquare Toronto (YYZ2) 62.2 km
- Cyxtera Toronto YYZ2 62.3 km · 19 MW
More eStruxture Data Centers data centers
- eStruxture CAL-1 Canada
- eStruxture CAL-2 Canada
- eStruxture MTL-1 Canada
- eStruxture MTL-2 Canada
- eStruxture MTL-3 Canada
- eStruxture TOR-2 Canada
- eStruxture TOR-3 Canada
- eStruxture TOR-4 Canada
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.