HEB data center in San Antonio

HEB data center in San Antonio is an operational data center operated by HEB in San Antonio, United States. Our footprint estimate of its power is about 6.8 MW.

Key facts

StatusOperational
OperatorHEB
Facility power6.8 MW (range 3.4 MW to 11 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 5,682 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,900 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressHuebner Road 15103, San Antonio
Coordinates29.58015, -98.54130

Power and grid

Nearest high-voltage substationDe Zavala Road Substation, 138 kV, 2.6 km away (CPS Energy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationHill Country Substation, 345 kV, 5.3 km away
HV substations within 10 km18
UtilityCity Of San Antonio (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityERCO
Nearest gas pipelineEl Paso Texas Pipeline Co, intrastate pipeline, 3.3 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km6.3 GW in 28 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity379 g CO₂ per kWh (Texas, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8%
Industrial power priceUSD 0.072 per kWh (Texas, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature20.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature44.5 °C (2001 to 2025)
Cooling degree days1,804 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.84 kWh per m² per day
Wind at 50 m6.1 m/s average
Water stress todayHigh (40-80%) (Texas)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does HEB data center in San Antonio use?

We estimate the facility power at about 6.8 MW. Estimate from building footprint, low confidence.

How close is HEB data center in San Antonio to the power grid?

The nearest high-voltage substation in OpenStreetMap is De Zavala Road Substation (138 kV), about 2.6 km away. The local utility is City Of San Antonio, in the ERCO balancing area.

How clean is the power for HEB data center in San Antonio?

The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.

Who operates HEB data center in San Antonio?

HEB.