Stream Data Centers - San Antonio II

Stream Data Centers - San Antonio II is an operational data center operated by Stream Data Centers in San Antonio, United States. Our footprint estimate of its power is about 18 MW.

Key facts

StatusOperational
OperatorStream Data Centers
Facility power18 MW (range 8.9 MW to 28 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 14,809 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 7,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks
PeeringDB.
Also known asCyrusOne San Antonio IV · Stream San Antonio II
Address9550 Westover Hills Blvd
Coordinates29.47174, -98.67158
Websitestreamdatacenters.com/datacenters/san-antonio-ii

Power and grid

Nearest high-voltage substationVLSI Substation, 138 kV, 700 m away (CPS Energy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationCagnon Road Substation, 345 kV, 7.7 km away
HV substations within 10 km18
UtilityCity Of San Antonio (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityERCO
Nearest gas pipelineEl Paso Texas Pipeline Co, intrastate pipeline, 2.6 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km5.2 GW in 24 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity379 g CO₂ per kWh (Texas, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8%
Industrial power priceUSD 0.072 per kWh (Texas, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature20.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature44.5 °C (2001 to 2025)
Cooling degree days1,804 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.84 kWh per m² per day
Wind at 50 m6.1 m/s average
Water stress todayHigh (40-80%) (Texas)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Stream Data Centers - San Antonio II use?

We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.

How close is Stream Data Centers - San Antonio II to the power grid?

The nearest high-voltage substation in OpenStreetMap is VLSI Substation (138 kV), about 700 m away. The local utility is City Of San Antonio, in the ERCO balancing area.

How clean is the power for Stream Data Centers - San Antonio II?

The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.

Who operates Stream Data Centers - San Antonio II?

Stream Data Centers.