CyrusOne San Antonio II
CyrusOne San Antonio II is an operational data center operated by CyrusOne in Leon Valley, United States. Our footprint estimate of its power is about 19 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | CyrusOne |
| Facility power | 19 MW (range 9.4 MW to 30 MW) Estimate from building footprint, low confidence. Footprint estimate: about 15,673 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 8,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | CyrusOne San Antonio III |
| Coordinates | 29.47089, -98.67305 |
| Website | cyrusone.com/data-center-locations/texas/san-antonio-texas-ii |
Power and grid
| Nearest high-voltage substation | VLSI Substation, 138 kV, 600 m away (CPS Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Cagnon Road Substation, 345 kV, 7.5 km away |
| HV substations within 10 km | 18 |
| Utility | City Of San Antonio (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ERCO |
| Nearest gas pipeline | El Paso Texas Pipeline Co, intrastate pipeline, 2.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.2 GW in 24 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 20.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 44.5 °C (2001 to 2025) |
| Cooling degree days | 1,804 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.84 kWh per m² per day |
| Wind at 50 m | 6.1 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does CyrusOne San Antonio II use?
We estimate the facility power at about 19 MW. Estimate from building footprint, low confidence.
How close is CyrusOne San Antonio II to the power grid?
The nearest high-voltage substation in OpenStreetMap is VLSI Substation (138 kV), about 600 m away. The local utility is City Of San Antonio, in the ERCO balancing area.
How clean is the power for CyrusOne San Antonio II?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates CyrusOne San Antonio II?
CyrusOne.
Data centers near Leon Valley
- Stream Data Centers - San Antonio II 171 m · 18 MW
- Microsoft SAT14 854 m · 66 MW
- Microsoft SAT14 912 m · 18 MW
- CHRISTUS Health data center in Leon Valley 1.3 km · 8.9 MW
- Frost Bank data center in Leon Valley 1.4 km · 11 MW
- CyrusOne San Antonio 1.5 km · 4.7 MW
- Lowe's Data Center 1.6 km · 11 MW
- Microsoft 1.9 km · 37 MW
More CyrusOne data centers
- CyrusOne NVA5 United States
- CyrusOne FRA3 Germany
- CyrusOne Sterling United States
- CyrusOne Aurora I United States
- CyrusOne Sterling NVA9 United States
- CyrusOne NVA14 United States
- CyrusOne Lebanon United States
- CyrusOne NC-1 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.