Hotel des Telecoms
Hotel des Telecoms is an operational data center operated by Etix Everywhere in Labege Innopole, France. Our footprint estimate of its power is about 4.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Etix Everywhere |
| Facility power | 4.1 MW (range 2 MW to 6.5 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,699 m² building outline x 2 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 4 networks PeeringDB. |
| Also known as | Hôtel des Telecoms |
| Address | 40 rue du Village d'Entreprises |
| Coordinates | 43.54256, 1.50944 |
| Website | fullsave.com |
Power and grid
| Nearest high-voltage substation | Poste électrique de Saint-Orens, 225 kV, 1.1 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 6 |
| Power plants within 50 km | 410 MW in 56 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 13.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.8 °C (2001 to 2025) |
| Cooling degree days | 478 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.86 kWh per m² per day |
| Wind at 50 m | 5.1 m/s average |
| Water stress today | Low - Medium (10-20%) (Occitanie) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Hotel des Telecoms use?
We estimate the facility power at about 4.1 MW. Estimate from building footprint, low confidence.
How close is Hotel des Telecoms to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique de Saint-Orens (225 kV), about 1.1 km away.
How clean is the power for Hotel des Telecoms?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Hotel des Telecoms?
Etix Everywhere.
Data centers near Labege Innopole
- Centrinuity Toulouse 9.4 km · 0.8 MW
- 10 Rue des Frères Peuge 9.5 km
- Bouygues Télécom data center in Toulouse 10.6 km · 1.9 MW
- Cogent Toulouse 11.1 km · 2.2 MW
- Eurofiber DC - TLS00 11.1 km · 4.7 MW
- UltraEdge Toulouse 11.2 km
- Oscar 12.5 km · 8.4 MW
- EXA Edge DC Toulouse 12.7 km
More Etix Everywhere data centers
- ETIX Nantes #3 France
- Eurofiber DC - TLS00 France
- ETIX Lille #2 France
- ETIX Lille #1 France
- ETIX Paris #3 France
- ETIX Bangkok #1 Thailand
- ETIX BelgiumDC #1 Belgium
- ETIX Lille #3 France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.