ETIX BelgiumDC #1
ETIX BelgiumDC #1 is an operational data center operated by Etix Everywhere in Villers-le-Bouillet, Belgium. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Etix Everywhere |
| Networks | 4 networks PeeringDB. |
| Address | Rue de la Science 3, 4530 Villers-le-Bouillet |
| Coordinates | 50.57966, 5.26172 |
| Website | etixeverywhere.com/fr/etix-belgiumdc-1 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 150 kV, 4.9 km away (Elia) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Tihange, 380 kV, 5 km away |
| HV substations within 10 km | 7 |
| Power plants within 50 km | 5.9 GW in 18 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 151 g CO₂ per kWh (Belgium, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 33.5%, gas 20.8%, wind 18.6%, solar 14.5%, oil and other fossil 7.1%. Clean power: 72.1% |
| Industrial power price | EUR 0.133 per kWh (Belgium, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.7 °C (2001 to 2025) |
| Cooling degree days | 85 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.04 kWh per m² per day |
| Wind at 50 m | 6.7 m/s average |
| Water stress today | Extremely High (>80%) (Belgium) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is ETIX BelgiumDC #1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (150 kV), about 4.9 km away.
How clean is the power for ETIX BelgiumDC #1?
The grid in Belgium emits about 151 g CO₂ per kWh (2025). Largest sources: nuclear 33.5%, gas 20.8%, wind 18.6%.
Who operates ETIX BelgiumDC #1?
Etix Everywhere.
Data centers near Villers-le-Bouillet
- WDC 127 m · 3.4 MW
- EXA Edge DC Liege 28.2 km
- Hasselt DC1 39.2 km · 1.4 MW
- LCL Wallonia One 39.4 km · 13 MW
- Hasselt DC2 40.5 km · 7 MW
- Unix-Solutions DC Leuven 48.0 km
- Google Datacenter 51.1 km · 69 MW
- ENGIE Cofely (Maastricht-Airport) 53.3 km
More Etix Everywhere data centers
- ETIX Nantes #3 France
- Eurofiber DC - TLS00 France
- ETIX Lille #2 France
- Hotel des Telecoms France
- ETIX Lille #1 France
- ETIX Paris #3 France
- ETIX Bangkok #1 Thailand
- ETIX Lille #3 France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.