KOMO Plaza Seattle (Formerly Fisher Plaza)

KOMO Plaza Seattle (Formerly Fisher Plaza) is an operational data center operated by GI Property Management in Seattle, United States. Our footprint estimate of its power is about 38 MW.

Key facts

StatusOperational
OperatorGI Property Management
Facility power38 MW (range 19 MW to 60 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 5,236 m² building outline x 6 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 16,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks23 networks, 2 internet exchanges
PeeringDB.
Also known asEvocative SEA1 · TierPoint Seattle · KOMO Plaza East · KOMO Plaza West
Address140 4th Ave N
Opened2000
Coordinates47.61924, -122.34828
Websitekomoplaza.com

Power and grid

Nearest high-voltage substationBroad Street Substation, 115 kV, 300 m away (Seattle City Light)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationEast Pine Substation, 230 kV, 3.4 km away
HV substations within 10 km8
UtilityCity Of Seattle (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authoritySCL
Nearest gas pipelineNorthwest Pipeline, interstate pipeline, 20.6 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km126 MW in 7 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity135 g CO₂ per kWh (Washington, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 62.8%, gas 15.7%, wind 8.3%, nuclear 7.5%, coal 3%. Clean power: 80.9%
Industrial power priceUSD 0.074 per kWh (Washington, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature10.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature38 °C (2001 to 2025)
Cooling degree days79 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.42 kWh per m² per day
Wind at 50 m3.5 m/s average
Water stress todayLow - Medium (10-20%) (Washington)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does KOMO Plaza Seattle (Formerly Fisher Plaza) use?

We estimate the facility power at about 38 MW. Estimate from building footprint, low confidence.

How close is KOMO Plaza Seattle (Formerly Fisher Plaza) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Broad Street Substation (115 kV), about 300 m away. The local utility is City Of Seattle, in the SCL balancing area.

How clean is the power for KOMO Plaza Seattle (Formerly Fisher Plaza)?

The grid in Washington emits about 135 g CO₂ per kWh (2025). Largest sources: hydro 62.8%, gas 15.7%, wind 8.3%.

Who operates KOMO Plaza Seattle (Formerly Fisher Plaza)?

GI Property Management.