Equinix SE3 Data Center

Equinix SE3 Data Center is an operational data center operated by Equinix in Seattle, United States. Our footprint estimate of its power is about 11 MW.

Key facts

StatusOperational
OperatorEquinix
Facility power11 MW (range 5.3 MW to 17 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,763 m² building outline x 5 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 4,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Address5th Avenue 2020, 98121, Seattle
Opened1975
Coordinates47.61442, -122.33974
Websiteequinix.com/locations/united-states-colocation/seattle-data-centers/se3

Power and grid

Nearest high-voltage substationBroad Street Substation, 115 kV, 900 m away (Seattle City Light)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationEast Pine Substation, 230 kV, 2.7 km away
HV substations within 10 km7
UtilityCity Of Seattle (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authoritySCL
Nearest gas pipelineNorthwest Pipeline, interstate pipeline, 19.8 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km126 MW in 7 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity135 g CO₂ per kWh (Washington, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 62.8%, gas 15.7%, wind 8.3%, nuclear 7.5%, coal 3%. Clean power: 80.9%
Industrial power priceUSD 0.074 per kWh (Washington, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature10.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature38 °C (2001 to 2025)
Cooling degree days79 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.42 kWh per m² per day
Wind at 50 m3.5 m/s average
Water stress todayLow - Medium (10-20%) (Washington)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Equinix SE3 Data Center use?

We estimate the facility power at about 11 MW. Estimate from building footprint, low confidence.

How close is Equinix SE3 Data Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is Broad Street Substation (115 kV), about 900 m away. The local utility is City Of Seattle, in the SCL balancing area.

How clean is the power for Equinix SE3 Data Center?

The grid in Washington emits about 135 g CO₂ per kWh (2025). Largest sources: hydro 62.8%, gas 15.7%, wind 8.3%.

Who operates Equinix SE3 Data Center?

Equinix.

Data centers near Seattle

More Equinix data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.