NorthC Frankfurt 3
NorthC Frankfurt 3 is an operational data center operated by NorthC Deutschland in Frankfurt am Main, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | NorthC Deutschland |
| Networks | 9 networks PeeringDB. |
| Address | Rüsselsheimer Str. 22 |
| Coordinates | 50.10276, 8.61972 |
| Website | northcdatacenters.com/de |
Power and grid
| Nearest high-voltage substation | Umspannwerk Kleyerstraße, 110 kV, 1 km away (Netzdienste Rhein-Main) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Südwest, 380 kV, 1.2 km away |
| HV substations within 10 km | 36 |
| Power plants within 50 km | 3.3 GW in 44 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is NorthC Frankfurt 3 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Kleyerstraße (110 kV), about 1 km away.
How clean is the power for NorthC Frankfurt 3?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates NorthC Frankfurt 3?
NorthC Deutschland.
Data centers near Frankfurt am Main
- NorthC Frankfurt 3 97 m · 10 MW
- servinga data center in Gallus 186 m · 8.5 MW
- aixit Frankfurt 733 m · 7.4 MW
- ITENOS Frankfurt (FRA1) 924 m · 14 MW
- Equinix FR5 - Frankfurt, KleyerStrasse 978 m · 37 MW
- Telehouse - Frankfurt 979 m · 3.2 MW
- Telehouse data center in Frankfurt am Main 1.0 km · 13 MW
- NewColo Frankfurt 1.0 km
More NorthC Deutschland data centers
- NorthC Munich 2 Germany
- NorthC Hamburg Germany
- NorthC Berlin Germany
- NorthC Duesseldorf Germany
- NorthC Munich 1 Germany
- NorthC Nürnberg Germany