QTS Santa Clara 2

QTS Santa Clara 2 is an operational data center operated by Quality Technology Services in Santa Clara, United States. Our footprint estimate of its power is about 5.3 MW.

Key facts

StatusOperational
OperatorQuality Technology Services
Facility power5.3 MW (range 2.6 MW to 8.4 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 4,400 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,300 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressMission College Boulevard 2805, 95054
Coordinates37.39273, -121.97843
Websiteqtsdatacenters.com/data-centers/santa-clara

Power and grid

Nearest high-voltage substationUnnamed substation, 230 kV, 1.5 km away (Silicon Valley Power)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km29
UtilityCity Of Santa Clara (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityCISO
Nearest gas pipelineCalifornia Gas Transmission Co, intrastate pipeline, 700 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km2.1 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity189 g CO₂ per kWh (California, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7%
Industrial power priceUSD 0.241 per kWh (California, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature14 °C
NASA POWER, average of 2001 to 2025.
Highest temperature45.3 °C (2001 to 2025)
Cooling degree days370 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.32 kWh per m² per day
Wind at 50 m4.6 m/s average
Water stress todayExtremely High (>80%) (California)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does QTS Santa Clara 2 use?

We estimate the facility power at about 5.3 MW. Estimate from building footprint, low confidence.

How close is QTS Santa Clara 2 to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (230 kV), about 1.5 km away. The local utility is City Of Santa Clara, in the CISO balancing area.

How clean is the power for QTS Santa Clara 2?

The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.

Who operates QTS Santa Clara 2?

Quality Technology Services.