EdgeCore Silicon Valley
EdgeCore Silicon Valley is an operational data center operated by EdgeCore Digital Infrastructure in Santa Clara, United States. Our footprint estimate of its power is about 14 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | EdgeCore Digital Infrastructure |
| Facility power | 14 MW (range 7 MW to 23 MW) Estimate from building footprint, low confidence. Footprint estimate: about 11,727 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 6,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | 2201 Laurelwood Rd |
| Coordinates | 37.38469, -121.96492 |
| Website | edgecore.com/locations/locations |
Power and grid
| Nearest high-voltage substation | Scott Receiving Station, 115 kV, 1.2 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Northern Receiving Station, 230 kV, 1.9 km away |
| HV substations within 10 km | 30 |
| Utility | City Of Santa Clara (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | CISO |
| Nearest gas pipeline | California Gas Transmission Co, intrastate pipeline, 500 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.1 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 14 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 370 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.32 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does EdgeCore Silicon Valley use?
We estimate the facility power at about 14 MW. Estimate from building footprint, low confidence.
How close is EdgeCore Silicon Valley to the power grid?
The nearest high-voltage substation in OpenStreetMap is Scott Receiving Station (115 kV), about 1.2 km away. The local utility is City Of Santa Clara, in the CISO balancing area.
How clean is the power for EdgeCore Silicon Valley?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates EdgeCore Silicon Valley?
EdgeCore Digital Infrastructure.
Data centers near Santa Clara
- Evocative SJC11 586 m · 7.5 MW
- Amazon 590 m · 9.8 MW
- Digital Realty SJC (3205 Alfred St) 799 m
- Digital Realty SJC (3105 Alfred St) 934 m · 4.1 MW
- OpenColo 1.0 km · 5.8 MW
- CoreSite - Santa Clara (SV8) 1.0 km · 3.9 MW
- CoreSite - Santa Clara (SV4) 1.1 km · 4.4 MW
- Equinix SV2 - Silicon Valley, Santa Clara 1.1 km · 7.3 MW
More EdgeCore Digital Infrastructure data centers
- EdgeCore VA1 United States
- EdgeCore Phoenix United States
- EdgeCore Reno 1 United States
- EdgeCore VA2 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.