University of New Hampshire data center in Durham

University of New Hampshire data center in Durham is an operational data center operated by University of New Hampshire in Durham, United States. Our footprint estimate of its power is about 4.2 MW.

Key facts

StatusOperational
OperatorUniversity of New Hampshire
Facility power4.2 MW (range 2.1 MW to 6.8 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 3,533 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,800 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressLeavitt Lane 1, 03824
Coordinates43.14362, -70.95245

Power and grid

Nearest high-voltage substationMadbury Substation, 115 kV, 2.5 km away (Eversource)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationElliot Substation, 345 kV, 11.2 km away
HV substations within 10 km2
UtilityUnitil Energy Systems (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityISNE
Nearest gas pipelineGranite State Gas Trans Co, interstate pipeline, 8.4 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.5 GW in 33 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity180 g CO₂ per kWh (New Hampshire, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 55.3%, gas 27%, hydro 6.9%, bioenergy 4.1%, wind 2.4%. Clean power: 70.7%
Industrial power priceUSD 0.173 per kWh (New Hampshire, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature8.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.9 °C (2001 to 2025)
Cooling degree days297 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.76 kWh per m² per day
Wind at 50 m4.5 m/s average
Water stress todayLow - Medium (10-20%) (New Hampshire)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does University of New Hampshire data center in Durham use?

We estimate the facility power at about 4.2 MW. Estimate from building footprint, low confidence.

How close is University of New Hampshire data center in Durham to the power grid?

The nearest high-voltage substation in OpenStreetMap is Madbury Substation (115 kV), about 2.5 km away. The local utility is Unitil Energy Systems, in the ISNE balancing area.

How clean is the power for University of New Hampshire data center in Durham?

The grid in New Hampshire emits about 180 g CO₂ per kWh (2025). Largest sources: nuclear 55.3%, gas 27%, hydro 6.9%.

Who operates University of New Hampshire data center in Durham?

University of New Hampshire.

Data centers near Durham

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.