DataBank Denver (DEN4)

DataBank Denver (DEN4) is an operational data center operated by DataBank in Westminster, United States. Our footprint estimate of its power is about 2.7 MW.

Key facts

StatusOperational
OperatorDataBank
Facility power2.7 MW (range 1.4 MW to 4.4 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 2,283 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,200 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks1 networks
PeeringDB.
Also known asDataBank - DEN4
Address7579 W 103rd Ave
Coordinates39.88455, -105.08013
Websitedatabank.com/data-centers/denver/den4

Power and grid

Nearest high-voltage substationBroomfield Substation, 115 kV, 2.6 km away (Public Service Company of Colorado)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationSimms Substation, 230 kV, 5.9 km away
HV substations within 10 km7
UtilityPublic Service Co Of Colorado (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPSCO
Nearest gas pipelineColorado Interstate Gas Co, interstate pipeline, 27 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km6.9 GW in 70 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity400 g CO₂ per kWh (Colorado, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 30.6%, wind 29%, coal 23.7%, solar 13.2%, hydro 3.2%. Clean power: 45.6%
Industrial power priceUSD 0.100 per kWh (Colorado, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature10.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.9 °C (2001 to 2025)
Cooling degree days485 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.72 kWh per m² per day
Wind at 50 m5.4 m/s average
Water stress todayExtremely High (>80%) (Colorado)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does DataBank Denver (DEN4) use?

We estimate the facility power at about 2.7 MW. Estimate from building footprint, low confidence.

How close is DataBank Denver (DEN4) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Broomfield Substation (115 kV), about 2.6 km away. The local utility is Public Service Co Of Colorado, in the PSCO balancing area.

How clean is the power for DataBank Denver (DEN4)?

The grid in Colorado emits about 400 g CO₂ per kWh (2025). Largest sources: gas 30.6%, wind 29%, coal 23.7%.

Who operates DataBank Denver (DEN4)?

DataBank.