Datacenter Bouygues Télécom
Datacenter Bouygues Télécom is an operational data center operated by Bouygues Télécom in Villeneuve-Saint-Georges, France. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Bouygues Télécom |
| Coordinates | 48.72561, 2.47095 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 225 kV, 3.5 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 13 |
| Power plants within 50 km | 2.3 GW in 52 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 11.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 152 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.31 kWh per m² per day |
| Wind at 50 m | 6.2 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Datacenter Bouygues Télécom to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (225 kV), about 3.5 km away.
How clean is the power for Datacenter Bouygues Télécom?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Datacenter Bouygues Télécom?
Bouygues Télécom.
Data centers near Villeneuve-Saint-Georges
- Goodman PAR02 A&B Data Centre Campus 4.1 km · 19 MW
- MEDIACTIVE MN3 5.0 km
- OPCORE - DC3 / PAR3 8.7 km · 16 MW
- OPCORE - DC2 / PAR2 8.8 km · 3.7 MW
- Datacenter Société Generale 9.0 km · 8.3 MW
- Digital Realty Paris PAR6 11.1 km · 6.7 MW
- Commissariat a l'Energie Atomique Topaze 11.7 km · 0.2 MW
- Aqua Ray Aurora 11.9 km
More Bouygues Télécom data centers
- Datacenter Bouygues Télécom France
- Datacenter Bouygues Télécom France
- Bouygues Telecom data center in Cabriès France
- Bouygues Télécom data center in Montpellier France
- Bouygues Télécom data center in Poitiers France
- Bouygues Télécom data center in Toulouse France
- Bouygues Télécom data center in Léognan France
- Bouygues Télécom data center in Nanterre France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.