Digital Realty Copenhagen CPH1-3 is an operational data center operated by Digital Realty in Copenhagen, Denmark. Our footprint estimate of its power is about 8.9 MW.

Key facts

StatusOperational
OperatorDigital Realty
Facility power8.9 MW (range 4.5 MW to 14 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 7,431 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,800 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks99 networks, 7 internet exchanges
PeeringDB.
Also known asDigital Realty Copenhagen CPH2 · Digital Realty Copenhagen CPH1
AddressIndustriparken 20A, Ballerup
Coordinates55.72809, 12.37748
Websitedigitalrealty.com/data-centers/copenhagen/industriparken-area-ballerup-denmark

Power and grid

Nearest high-voltage substationBallerupgård transformerstation, 132 kV, 400 m away (Energinet)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationGlentegård transformerstation, 400 kV, 8.1 km away
HV substations within 10 km13
Power plants within 50 km2.2 GW in 17 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity120 g CO₂ per kWh (Denmark, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 56.9%, bioenergy 21.4%, solar 12.8%, oil and other fossil 4.9%, coal 2.5%. Clean power: 91.2%
Industrial power priceEUR 0.118 per kWh (Denmark, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9 °C
NASA POWER, average of 2001 to 2025.
Highest temperature30 °C (2001 to 2025)
Cooling degree days44 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.91 kWh per m² per day
Wind at 50 m7.6 m/s average
Water stress todayLow (<10%) (Denmark)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low (<10%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Digital Realty Copenhagen CPH1-3 use?

We estimate the facility power at about 8.9 MW. Estimate from building footprint, low confidence.

How close is Digital Realty Copenhagen CPH1-3 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Ballerupgård transformerstation (132 kV), about 400 m away.

How clean is the power for Digital Realty Copenhagen CPH1-3?

The grid in Denmark emits about 120 g CO₂ per kWh (2025). Largest sources: wind 56.9%, bioenergy 21.4%, solar 12.8%.