EdgeConneX Nashville (EDCNAS01)
EdgeConneX Nashville (EDCNAS01) is an operational data center operated by EdgeConneX in Nashville, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | EdgeConneX |
| Networks | 5 networks PeeringDB. |
| Address | 1841 Air Lane Dr, Building 3 |
| Coordinates | 36.14488, -86.70172 |
| Website | edgeconnex.com |
Power and grid
| Nearest high-voltage substation | South Nashville Substation, 161 kV, 4.1 km away (Tennessee Valley Authority) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Pin Hook Substation, 500 kV, 13.9 km away |
| HV substations within 10 km | 7 |
| Utility | Nashville Electric Service (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | TVA |
| Nearest gas pipeline | Gulf Xpress, interstate pipeline, 9.6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.1 GW in 10 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 363 g CO₂ per kWh (Tennessee, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 39.2%, coal 24.1%, gas 23.5%, hydro 10.5%, solar 1.9%. Clean power: 52.2% |
| Industrial power price | USD 0.069 per kWh (Tennessee, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 14.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.5 °C (2001 to 2025) |
| Cooling degree days | 897 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.23 kWh per m² per day |
| Wind at 50 m | 5.1 m/s average |
| Water stress today | Low - Medium (10-20%) (Tennessee) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is EdgeConneX Nashville (EDCNAS01) to the power grid?
The nearest high-voltage substation in OpenStreetMap is South Nashville Substation (161 kV), about 4.1 km away. The local utility is Nashville Electric Service, in the TVA balancing area.
How clean is the power for EdgeConneX Nashville (EDCNAS01)?
The grid in Tennessee emits about 363 g CO₂ per kWh (2025). Largest sources: nuclear 39.2%, coal 24.1%, gas 23.5%.
Who operates EdgeConneX Nashville (EDCNAS01)?
EdgeConneX.
Data centers near Nashville
- Peace Communications NSH2 5.5 km
- Data center in Nashville 5.6 km · 1.2 MW
- XO Nashville 6.5 km
- Level(3) Nashville (Sidco Drive) 6.7 km
- IRIS - Nashville 7.0 km
- H5 Data Centers Nashville 7.2 km
- Zayo Nashville - 209 10th Ave. S 7.3 km
- Level(3) Nashville (9th Ave) 10.4 km
More EdgeConneX data centers
- EdgeConneX PHX02 Data Center United States
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConnex DUB04 Ireland
- EdgeConneX Germany
- EdgeConneX Chicago (EDCCHI02) United States
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConnex - DEN02 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.