Equinix data center
Equinix data center is an operational data center operated by Equinix in Pudahuel, Chile. Our footprint estimate of its power is about 3.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 3.1 MW (range 1.2 MW to 7.7 MW) Estimate from building footprint, low confidence. Footprint estimate: about 25,821 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 1,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | ST1 · ST2 |
| Address | Los Vientos 20239, Pudahuel |
| Coordinates | -33.44790, -70.85147 |
| Website | equinix.lat |
Power and grid
| Nearest high-voltage substation | Subestación Seccionadora Lo Aguirre, 500 kV, 4.4 km away (Transelec S.A.) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 3 |
| Power plants within 50 km | 1.1 GW in 92 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 291 g CO₂ per kWh (Chile, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 25.1%, hydro 22.2%, coal 17.8%, gas 15.3%, wind 13.1%. Clean power: 66.4% |
Climate and water
| Average temperature | 14.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.8 °C (2001 to 2025) |
| Cooling degree days | 298 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.42 kWh per m² per day |
| Wind at 50 m | 3.4 m/s average |
| Water stress today | Extremely High (>80%) (Chile) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix data center use?
We estimate the facility power at about 3.1 MW. Estimate from building footprint, low confidence.
How close is Equinix data center to the power grid?
The nearest high-voltage substation in OpenStreetMap is Subestación Seccionadora Lo Aguirre (500 kV), about 4.4 km away.
How clean is the power for Equinix data center?
The grid in Chile emits about 291 g CO₂ per kWh (2025). Largest sources: solar 25.1%, hydro 22.2%, coal 17.8%.
Who operates Equinix data center?
Equinix.
Data centers near Pudahuel
- Equinix ST1/ST2 - Santiago 293 m
- Data Center L7 10.1 km · 0.6 MW
- Amazon Web Services 12.6 km · 4.8 MW
- Odata Data Center 16.1 km · 14 MW
- GTD Chile - Panamericana 16.5 km
- Data Center GTD 16.5 km · 3.1 MW
- SONDA - Quilicura 17.4 km · 2.1 MW
- IBM data center / Centro Tecnológico San Bernardo 17.5 km · 1.6 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.