Equinix FR4 - Frankfurt, West
Equinix FR4 - Frankfurt, West is an operational data center operated by Equinix in Frankfurt, Germany. Our footprint estimate of its power is about 6.5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 6.5 MW (range 2.6 MW to 16 MW) Estimate from building footprint, low confidence. Footprint estimate: about 54,521 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 2,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 117 networks, 10 internet exchanges PeeringDB. |
| Also known as | Equinix FR6 - Frankfurt, West · Equinix FR8 - Frankfurt, West · Equinix Germany GmbH · Equinix FR4 · Equinix FR8.2 · Equinix FR6 |
| Address | Lärchenstrasse 110 |
| Opened | 2017-06-29 |
| Coordinates | 50.09794, 8.58796 |
| Website | equinix.com/locations/germany-colocation/frankfurt-data-centers/fr4 |
Power and grid
| Nearest high-voltage substation | Umspannwerk Froschhäuser Straße, 110 kV, 500 m away (Netzdienste Rhein-Main) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Südwest, 380 kV, 2.3 km away |
| HV substations within 10 km | 33 |
| Power plants within 50 km | 3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix FR4 - Frankfurt, West use?
We estimate the facility power at about 6.5 MW. Estimate from building footprint, low confidence.
How close is Equinix FR4 - Frankfurt, West to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Froschhäuser Straße (110 kV), about 500 m away.
How clean is the power for Equinix FR4 - Frankfurt, West?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Equinix FR4 - Frankfurt, West?
Equinix.
Data centers near Frankfurt
- FKQ I Data Center 371 m · 59 MW
- NorthC Frankfurt 3 2.3 km
- NorthC Frankfurt 3 2.4 km · 10 MW
- servinga data center in Gallus 2.4 km · 8.5 MW
- Colt FRA3 3.0 km · 5.8 MW
- aixit Frankfurt 3.0 km · 7.4 MW
- Telehouse data center in Frankfurt am Main 3.0 km · 13 MW
- Telehouse - Frankfurt 3.0 km · 3.2 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.