Menlo Digital MD-VA1
Menlo Digital MD-VA1 is an operational data center in Oak Hill, United States. Its power is about 62 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 62 MW Derived from a tagged IT power value. IT power tag in OpenStreetMap |
| IT power | 48 MW |
| GPU capacity if all AI | about 27,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | McLearen Road 13775, 20171 |
| Coordinates | 38.92721, -77.42393 |
| Website | menlo-digital.com/portfolio/md-va1-herndon |
Power and grid
| Nearest high-voltage substation | Lincoln Park Substation, 230 kV, 500 m away (Virginia Electric and Power Company) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 40 |
| Utility | Virginia Electric & Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Columbia Gas Trans Co, interstate pipeline, 1.9 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.2 GW in 43 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 729 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.98 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Menlo Digital MD-VA1 use?
Public data puts the facility power at about 62 MW. Derived from a tagged IT power value.
How close is Menlo Digital MD-VA1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Lincoln Park Substation (230 kV), about 500 m away. The local utility is Virginia Electric & Power Co, in the PJM balancing area.
How clean is the power for Menlo Digital MD-VA1?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Data centers near Oak Hill
- Amazon IAD-167 540 m · 12 MW
- 365 Data Centers Herndon (VA1) 903 m
- Data center in Herndon 942 m · 14 MW
- Amazon IAD-500 1.0 km · 28 MW
- Amazon IAD-135 3.6 km · 21 MW
- Amazon IAD-9 4.0 km · 14 MW
- 4120 Lafayette Center Drive 4.6 km · 4.7 MW
- H5 Data Centers Virginia (4030) 4.6 km · 20 MW