NTT Serangoon Data Center (SG1)
NTT Serangoon Data Center (SG1) is an operational data center operated by NTT Global Data Centers in Singapore, Singapore. Our footprint estimate of its power is about 0.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 0.7 MW (range 0.3 MW to 1.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,471 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 7 networks, 1 internet exchanges PeeringDB. |
| Also known as | NTT Communications Singapore Serangoon Data Center |
| Address | 51 Serangoon North Avenue 4 |
| Opened | 2012 |
| Coordinates | 1.37612, 103.87509 |
| Website | datacenter.hello.global.ntt/en/location/singapore/serangoon-data-center |
Power and grid
| Nearest high-voltage substation | Paya Lebar 400kV, 400 kV, 5.5 km away (SPPG) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 6 |
| Power plants within 50 km | 19 GW in 38 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 497 g CO₂ per kWh (Singapore, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 91.1%, bioenergy 2.8%, solar 2.7%, oil and other fossil 2.5%, coal 0.9%. Clean power: 5.5% |
Climate and water
| Average temperature | 27.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.9 °C (2001 to 2025) |
| Cooling degree days | 3,296 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.82 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | NoData (Singapore) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTT Serangoon Data Center (SG1) use?
We estimate the facility power at about 0.7 MW. Estimate from building footprint, low confidence.
How close is NTT Serangoon Data Center (SG1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Paya Lebar 400kV (400 kV), about 5.5 km away.
How clean is the power for NTT Serangoon Data Center (SG1)?
The grid in Singapore emits about 497 g CO₂ per kWh (2025). Largest sources: gas 91.1%, bioenergy 2.8%, solar 2.7%.
Who operates NTT Serangoon Data Center (SG1)?
NTT Global Data Centers.
Data centers near Singapore
- Keppel Data Centres | Keppel DC Singapore 1 111 m · 0.7 MW
- PrincetonDG SG1 Singapore 337 m
- Iron Mountain Data Center - Singapore (SIN-1) 405 m · 0.6 MW
- Starhub Data Center @ Ang Mo Kio 586 m
- 1ASIA-Singapore 3.1 km
- STT Defu 3 3.4 km · 27 MW
- STTGDC SIN1 3.5 km · 1.9 MW
- CapitaLand data center in Singapore 4.3 km · 40 MW
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom