Pulsant data center in Milton Keynes
Pulsant data center in Milton Keynes is an operational data center operated by Pulsant in Milton Keynes, United Kingdom. Our footprint estimate of its power is about 4.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Pulsant |
| Facility power | 4.7 MW (range 2.4 MW to 7.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,953 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | Pulsant Milton Keynes SE-1 |
| Coordinates | 52.05469, -0.75724 |
| Website | pulsant.com/colocation-milton-keynes-datacentre |
Power and grid
| Nearest high-voltage substation | Bradwell Abbey Substation, 132 kV, 2.7 km away (National Grid Electricity Distribution Plc) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Marston Vale Substation, 400 kV, 15.6 km away |
| HV substations within 10 km | 3 |
| Power plants within 50 km | 2.5 GW in 107 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 9.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.2 °C (2001 to 2025) |
| Cooling degree days | 33 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.88 kWh per m² per day |
| Wind at 50 m | 7.1 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Pulsant data center in Milton Keynes use?
We estimate the facility power at about 4.7 MW. Estimate from building footprint, low confidence.
How close is Pulsant data center in Milton Keynes to the power grid?
The nearest high-voltage substation in OpenStreetMap is Bradwell Abbey Substation (132 kV), about 2.7 km away.
How clean is the power for Pulsant data center in Milton Keynes?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Who operates Pulsant data center in Milton Keynes?
Pulsant.
Data centers near Milton Keynes
- nLighten Milton Keynes 4.4 km · 7.6 MW
- nLighten Milton Keynes LTN1 4.6 km
- Creslow Park 18.9 km
- Data center in Aylesbury 19.0 km · 1.1 MW
- Hellermann Tyton Data 22.8 km · 2.7 MW
- Data center in Dunstable 24.7 km · 8.6 MW
- Starwood House 38.5 km · 8.8 MW
- NTT Hemel Hempstead 2 Data Center (HH2) 38.8 km · 11 MW
More Pulsant data centers
- Pulsant Reading SE-3 (South) United Kingdom
- Pulsant Croydon LN-1 United Kingdom
- Pulsant Edinburgh SC-2 (Medway) United Kingdom
- Pulsant Edinburgh SC-3 (Newbridge) United Kingdom
- Pulsant Edinburgh SC-1 United Kingdom
- Pulsant Maidenhead SE-2 United Kingdom
- Pulsant Reading SE-4 (East) United Kingdom
- Pulsant Birmingham WM-1 United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.