Amazon Fadeley III

Amazon Fadeley III is an operational data center operated by Amazon Web Services in South Riding, United States. Our footprint estimate of its power is about 22 MW. Likely chips: AWS Trainium and NVIDIA GPUs (guess).

Key facts

StatusOperational
OperatorAmazon Web Services
Facility power22 MW (range 8.6 MW to 54 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 179,971 m² site outline x 0.12 kW per m² of land.
AI chipsAWS Trainium and NVIDIA GPUs
Guess from the operator, not confirmed. AWS deploys its own Trainium chips next to NVIDIA GPUs.
GPU capacity if all AIabout 9,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asAmazon IAD-81 · Amazon IAD-68 · Amazon IAD-62 · Amazon IAD-83 · AWS
Coordinates38.94827, -77.52154

Power and grid

Nearest high-voltage substationYardley Ridge Substation, 230 kV, 300 m away (NOVEC)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km48
UtilityNorthern Virginia Elec Coop (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineDominion Transmission Co, interstate pipeline, 400 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km2.3 GW in 33 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity357 g CO₂ per kWh (Virginia, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39%
Industrial power priceUSD 0.100 per kWh (Virginia, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.7 °C (2001 to 2025)
Cooling degree days729 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.98 kWh per m² per day
Wind at 50 m5.3 m/s average
Water stress todayMedium - High (20-40%) (Virginia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Amazon Fadeley III use?

We estimate the facility power at about 22 MW. Estimate from building footprint, low confidence.

What chips does Amazon Fadeley III use?

No chips are reported. Based on the operator, the likely chips are AWS Trainium and NVIDIA GPUs.

How close is Amazon Fadeley III to the power grid?

The nearest high-voltage substation in OpenStreetMap is Yardley Ridge Substation (230 kV), about 300 m away. The local utility is Northern Virginia Elec Coop, in the PJM balancing area.

How clean is the power for Amazon Fadeley III?

The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.

Who operates Amazon Fadeley III?

Amazon Web Services.

Data centers near South Riding

More Amazon Web Services data centers

Sources

Correct this page or get the data