Data Center Directory

Cologix NNJ3

Cologix NNJ3 is an operational data center operated by Cologix in Parsippany, United States. No power figure is public for this site yet.

Key facts

StatusOperational
OperatorCologix
Networks7 networks
PeeringDB.
Address200 Webro Road
Coordinates40.85708, -74.41891
Websitecologix.com

Power and grid

Nearest high-voltage substationStoneybrook Substation, 230 kV, 2.7 km away (Jersey Central Power and Light)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km8
UtilityJersey Central Power & Lt Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineAlgonquin Gas Trans Co, interstate pipeline, 1.9 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km17 GW in 152 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity265 g CO₂ per kWh (New Jersey, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 45.8%, nuclear 43.2%, solar 9%, oil and other fossil 1.5%, bioenergy 0.9%. Clean power: 52.8%
Industrial power priceUSD 0.162 per kWh (New Jersey, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature10.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.4 °C (2001 to 2025)
Cooling degree days465 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.77 kWh per m² per day
Wind at 50 m4.5 m/s average
Water stress todayMedium - High (20-40%) (New Jersey)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How close is Cologix NNJ3 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Stoneybrook Substation (230 kV), about 2.7 km away. The local utility is Jersey Central Power & Lt Co, in the PJM balancing area.

How clean is the power for Cologix NNJ3?

The grid in New Jersey emits about 265 g CO₂ per kWh (2025). Largest sources: gas 45.8%, nuclear 43.2%, solar 9%.

Who operates Cologix NNJ3?

Cologix.

Data centers near Parsippany

More Cologix data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.