Equinix DC16
Equinix DC16 is an operational data center operated by Equinix in Ashburn, United States. Our footprint estimate of its power is about 67 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 67 MW (range 33 MW to 107 MW) Estimate from building footprint, low confidence. Footprint estimate: about 13,877 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 29,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 1 networks, 1 internet exchanges PeeringDB. |
| Also known as | Equinix DC17 · Equinix Ashburn DC18 |
| Address | 44740 Performance Circle |
| Coordinates | 39.02420, -77.45228 |
| Website | equinix.com/data-centers/americas-colocation/united-states-colocation/washington-dc-data-centers/dc16 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 230 kV, 400 m away (Virginia Electric & Power Company) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 47 |
| Utility | Virginia Electric & Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Columbia Gas Trans Co, interstate pipeline, 3.9 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 1.6 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 729 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.98 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix DC16 use?
We estimate the facility power at about 67 MW. Estimate from building footprint, low confidence.
How close is Equinix DC16 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (230 kV), about 400 m away. The local utility is Virginia Electric & Power Co, in the PJM balancing area.
How clean is the power for Equinix DC16?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Who operates Equinix DC16?
Equinix.
Data centers near Ashburn
- Amazon Web Services Datacenter Complex 243 m · 49 MW
- Equinix DC12 253 m · 24 MW
- Centersquare Northern Virginia (IAD4) 266 m · 24 MW
- RagingWire VA1 - NTT 298 m · 16 MW
- Equinix DC10 362 m · 27 MW
- RagingWire VA2 - NTT 462 m · 18 MW
- Lumen Ashburn 512 m · 9.2 MW
- CyrusOne NVA14 536 m · 47 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.