euNetworks Colocation Nuernberg
euNetworks Colocation Nuernberg is an operational data center operated by euNetworks in Nuremberg, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | euNetworks |
| Networks | 2 networks PeeringDB. |
| Address | Fuerther Strasse 212 |
| Coordinates | 49.45971, 11.03472 |
| Website | euNetworks.com |
Power and grid
| Nearest high-voltage substation | Umspannwerk Sigmundstraße, 110 kV, 1.7 km away (N-ERGIE Netz) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Kriegenbrunn, 380 kV, 11.9 km away |
| HV substations within 10 km | 20 |
| Power plants within 50 km | 1.3 GW in 23 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 8.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.4 °C (2001 to 2025) |
| Cooling degree days | 156 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.14 kWh per m² per day |
| Wind at 50 m | 5.9 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is euNetworks Colocation Nuernberg to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Sigmundstraße (110 kV), about 1.7 km away.
How clean is the power for euNetworks Colocation Nuernberg?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates euNetworks Colocation Nuernberg?
euNetworks.
Data centers near Nuremberg
- nLighten Nuremberg NUE1 1.6 km
- Hetzner Online NBG1 (Nuremberg) 1.8 km · 6.2 MW
- Deutschherrnkarree 2.2 km
- noris network datacenter.de NBG3 / NBG4 2.2 km
- ScaleUp Datacenter NUE1 2.2 km
- ADESTIS Nürnberg NBG1 (Alte Dampfbäckerei) 3.9 km
- noris network datacenter.de NBG6 8.8 km · 10 MW
- NorthC Nürnberg 12.9 km
More euNetworks data centers
- euNetworks Colocation Hamburg Germany
- euNetworks Amsterdam Netherlands
- euNetworks (Global Voice) Ireland
- euNetworks Colocation Karlsruhe Germany
- euNetworks Colocation Dortmund Germany
- euNetworks Colocation Bielefeld Germany
- euNetworks Colocation Bremen Germany
- euNetworks Colocation Dresden Germany